Dual-column capillary microextraction combined with ETV-ICP-MS for the speciation of arsenic in human hair extracts

Skip to Navigation

Ezine

  • Published: Mar 1, 2010
  • Channels: Atomic

Dual-column capillary microextraction (CME) combined with electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS) for the speciation of arsenic in human hair extracts

Journal of Mass Spectrometry 2010, 24, 205-214
Fei Zheng, Bin Hu

Abstract: In this work, dual-column capillary microextraction (CME) system consisting of N-(2-aminoethyl)-3-aminopropyltrimethoxysilane (AAPTS)-silica coated capillary (C1) and 3-mercaptopropyl trimethoxysilane (MPTS)-silica coated capillary (C2) was developed for sequential separation/preconcentration of arsenite [As(III)], arsenate [As(V)], monomethylarsonic acid [MMA(V)] and dimethylarsinic acid [DMA(V)] in the extracts of human hair followed by electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS) detection with iridium as permanent modifier. Various experimental parameters affecting the dual-column microextraction of different As species had been investigated in detail. It was found that at pH 9, As(V) and MMA could be quantitatively retained by C1 and only As(III) could be quantitatively retained by C2. With the aid of valve switching, As(V)/MMA(V) retained on C1 and As(III) retained on C2 could be sequentially desorbed by 10 µl of 0.01 mol l-1 HNO3 [for As(V)], 0.1 mol l-1 HNO3 [for MMA(V)] and 0.2 mol l-1 HNO3-3% thiourea (m/v) [for As(III)], respectively, the eluents were immediately introduced into the Ir-coated graphite tubes for further ETV-ICP-MS detection. With two-step ETV pyrolysis program, Cl- in the sample matrix could be in situ removed, and the total As in the human hair extracts or digested solution could be interference-free, determined by ETV-ICP-MS. DMA(V) in the human hair extracts was obtained by subtraction of total As in the human hair extracts from other three As species. Under the optimized conditions, the detection limits of the method were 3.9 pg ml-1 for As(III), 2.7 pg ml-1 for As(V), 2.6 pg ml-1 for MMA(V) and 124 pg ml-1 for total As with the relative standard deviations less than 7.0% (C = 0.1 ng ml-1, n = 7), and the enrichment factor was 286, 262 and 260 for As(III), As(V) and MMA(V), respectively. The developed method was successfully applied for the speciation of arsenic in the extracts of human hair.


 

     
     
hair

Social Links

Share This Links

Bookmark and Share

Microsites

Suppliers Selection
Societies Selection

Banner Ad

Click here to see
all job opportunities

Copyright Information

Interested in separation science? Visit our sister site separationsNOW.com

Copyright © 2013 John Wiley & Sons, Inc. All Rights Reserved