Melamine migration from tableware

Skip to Navigation

Blog Post

  • Published: Oct 16, 2012
  • Author: Steve Down
  • Channels: Atomic / Infrared Spectroscopy / UV/Vis Spectroscopy / X-ray Spectrometry / Chemometrics & Informatics / MRI Spectroscopy / NMR Knowledge Base / Base Peak / Raman / Proteomics

View comments on this post

The migration of melamine from tableware to food simulants has been measured by an ambient mass spectrometry method using a high-resolution instrument for extra sensitivity. Melamine is used in the preparation of melamine-formaldehyde resins which are moulded into cups, plates and the like but residual melamine can migrate from the objects into foods. A risk assessment by the US FDA suggested that melamine might cause conditions such as kidney stones and kidney failure, and even death. Its release from tableware has been the subject of many recent EU Rapid Alert System for Food and Feed (RASFF) notifications and the current EU safetly limit for humans is set to 2.5 mg/kg.

Scientists in Italy have devised a new method for measuring melamine migration using desorption electrospray ionisation mass spectrometry (DESI MS) which allows the rapid analysis of samples with minimal sample preparation. Monica Mattarozzi and colleagues from the University of Parma described their method in Talanta. A total of 44 old and new melamine items were exposed to 3% acetic acid as a food simulant and the degree of migration was assessed by analysing the extracts.

No melamine migrated from the old items, some up to 20 years old, presumably because all of it had already been lost, said Mattarozzi. However, when new mugs, tea cups, tumblers, cereal bowls, soup bowls, plates and mixing bowls were tested, migration was observed from some items, with two releasing melamine higher than the legal limit. It is also important to remember that exposure will occur repeatedly as the items are used again and again.

The DESI MS method will help to keep track of tableware safety and "will be very useful for high-throughput analysis as required for quality control applications."

Comments

There are currently no comments on this post.

Comment Form

You have to log in to comment on this post.

Log in using the form at the top of the page or register here.

Social Links

Share This Links

Bookmark and Share

Microsites

Suppliers Selection
Societies Selection

Banner Ad

Click here to see
all job opportunities

Copyright Information

Interested in separation science? Visit our sister site separationsNOW.com

Copyright © 2013 John Wiley & Sons, Inc. All Rights Reserved